| Model | DKFXRS-32 II BM/C2 | DKFXRS-32 II/C4 | |
| sumber daya | 380V 3N~ 50Hz | 380V 3N~ 50Hz | |
| Tingkat Kejut Anti-Elektrik | Kelas I | Kelas I | |
| Rating Proteksi Ingress | IPX 4 | IPX 4 | |
| Kondisi Kinerja 1 | Suhu sekitar (DB/WB):7/6°C Suhu Banyu (Mlebu/Metu):9/55°C | Suhu sekitar (DB/WB):7/6°C Suhu Banyu (Mlebu/Metu):9/55°C | |
| Kapasitas Pemanasan | W | 31500 | 32000 |
| Daya Input | W | 8050 | 8000 |
| COP | 3,91 | 4,00 | |
| Arus Kerja | A | 15,3 | 15,2 |
| Ngasilake Banyu Panas | L/h | 590 | 600 |
| Kondisi Kinerja 2 | Suhu sekitar (DB/WB):-7/-8°C Suhu Banyu (Mlebu/Metu):9/55°C | Suhu sekitar (DB/WB):-7/-8°C Suhu Banyu (Mlebu/Metu):9/55°C | |
| Kapasitas Pemanasan | W | 22000 | 19000 |
| Input daya | W | 7600 | 7150 |
| COP | 2,89 | 2,66 | |
| Arus Kerja | A | 14,4 | 13,6 |
| Ngasilake Banyu Panas | L/h | 410 | 360 |
| AHPF | 3,75 | 3,81 | |
| Operasi Suhu Sekitar. | -30~45°C | ||
| Input Daya Maks | W | 15000 | 12500 |
| Max Mlaku saiki | A | 28 | 24 |
| Suhu Banyu Outlet Max | ℃ | 60 | 60 |
| aliran banyu Rated | m³ / jam | 6,31 | 5,5 |
| Penurunan Tekanan Banyu | kPa | 50 | 90 |
| Tekanan Maks ing Dhuwur/ Sisih Tekanan Rendah | Mpa | 4.5/4.5 | 4.5/4.5 |
| Discharge sing diidini / Tekanan Sucion | Mpa | 4.5/1.5 | 4.5/1.5 |
| Max Tekanan ing Evaporator | MPa | 4,5 | 4,5 |
| Sambungan Pipa Banyu | DN40/1½” Utas wadon | DN40/1" Utas wadon | |
| Tekanan Swara (1m) | dB(A) | 70 | 70 |
| Refrigerant / Ngisi daya | R410A / 6,7 kg | R410A / 6,9 kg | |
| Ukuran (L * W * H) | mm | 1620×850×1200 | 1620×850×1200 |
| Bobot Net | kg | 253 | 270 |
| Standar: | GB/T 21362-2023;GB29541-2013 | GB/T 21362-2023;GB29541-2013 |